ISO 13485:2016 certified · Startup India (DPIIT) recognised · NVIDIA Inception program member +91 44 4690 0555info@medoqi.tech
Home/Quality & QMS/FDA QMSR readiness
United States · FDA

FDA QMSR Readiness

The Quality Management System Regulation has applied since 2 February 2026. It incorporates ISO 13485:2016 by reference, keeps FDA-specific requirements, and changes what investigators can see. We help you close the gaps and show objective evidence.

21 CFR Part 820ISO 13485:201621 CFR 803 · 806 · 830
What changed

Four changes that matter in an inspection

Structure

ISO 13485 by reference

Part 820 now incorporates ISO 13485:2016, so ISO clause structure and terminology replace most of the former QSR language.

FDA-specific

Additional requirements remain

FDA keeps requirements for areas such as complaint and servicing records, UDI, and labelling and packaging controls, with links to MDR reporting and corrections and removals.

Visibility

More records open to inspection

Management review, quality audit and supplier audit reports, previously exempt from FDA inspection, can now be reviewed.

Inspections

Updated inspection approach

FDA has updated its inspection approach for the QMSR, moving away from the QSIT model used under the QSR.

Our approach

From gap assessment to inspection readiness

  1. 01QSR-to-QMSR gap assessmentProcedures, records and one representative design file assessed clause by clause.
  2. 02Requirements mappingISO 13485 clauses and FDA-specific requirements mapped to your processes and owners.
  3. 03Legacy record reconciliationDHF, DMR and DHR content reconciled with the medical device file, design and development file and production records.
  4. 04Process remediationSupplier, complaint, design and risk management processes updated and evidenced.
  5. 05Mock inspectionObjective evidence prepared and tested in a QMSR-style mock inspection.
Terminology is not compliance

Renaming legacy DHF, DMR and DHR records does not on its own establish QMSR compliance. The content must meet the relevant ISO 13485 clauses and FDA-specific requirements.

Illustrative QMSR gap report extract · not from a client file

ReferenceFindingPriorityAction
21 CFR 820.35Complaint records do not capture the MDR reportability determination and rationaleCriticalRevise complaint form and procedure
ISO 13485 §5.6Management review minutes not structured for external review now that they are inspectableMajorNew template, retrain owners
ISO 13485 §7.3.10Legacy DHF index omits design transfer and change recordsMajorReconcile into the design and development file
21 CFR 820.45Labelling inspection before release not recorded on one lineMajorAdd inspection record and check
ISO 13485 §7.4.1Supplier evaluation criteria not proportionate to riskMinorRisk-based supplier criteria
Quality packages

Choose a starting point

Moving from QSR to QMSR

QMSR Readiness Assessment

Scope
Procedures, records and one design file
Outputs
Gap report, prioritised plan, readiness summary
Method
Document review, interviews, record sampling
Request this package →
Startups and new sites

ISO 13485 Implementation

Scope
Process architecture, procedures, records, training
Outputs
Certification-ready QMS, first internal audit and management review
Method
Phased build, pilot, internal audit, certification support
Request this package →
Upcoming NB, MDSAP or FDA audit

Audit Readiness Programme

Scope
Mock audit, CAPA, staff preparation
Outputs
Mock audit report, CAPA plan, front- and back-room plan
Method
Audit simulation using the auditor's methodology
Request this package →
No full-time QA capacity

Outsourced QMS Support

Scope
CAPA, change control, complaints, document control, management review
Outputs
Maintained QMS with monthly KPI reporting
Method
Dedicated or shared specialists under agreed service levels
Request this package →
Talk to our experts

Discuss your device, market or audit with a specialist

Share the device, its class and your target markets. A senior specialist will come back with the likely pathway, the evidence gaps we see and a practical plan.

Talk to our experts → Request an AI pilot sales@medoqi.tech · +91 44 4690 0555